Sanitary Sewer:



Rational Formula Runoff Coefficient table for Property Drainage

Rational Method Runoff Coefficients
Categorized by Surface
Forested
0.059—0.2
Asphalt
0.7—0.95
Brick
0.7—0.85
Concrete
0.8—0.95
Shingle roof
0.75—0.95
Lawns, well drained (sandy soil)
Up to 2% slope
0.05—0.1
2% to 7% slope
0.10—0.15
Over 7% slope
0.15—0.2
Lawns, poor drainage (clay soil)
Up to 2% slope
0.13—0.17
2% to 7% slope
0.18—0.22
Over 7% slope
0.25—0.35
Driveways, walkways
0.75—0.85
Categorized by Use
Farmland
0.05—0.3
Pasture
0.05—0.3
Unimproved
0.1—0.3
Parks
0.1—0.25
Cemeteries
0.1—0.25
Railroad yard
0.2—0.40
Playgrounds (except asphalt or concrete)
0.2—0.35
Business Districts
Neighborhood
0.5—0.7
City (downtown)
0.7—0.95
Residential

Single-family
0.3—0.5
Multi-plexes, detached
0.4—0.6
Multi-plexes, attached
0.6—0.75
Suburban
0.25—0.4
Apartments, condominiums
0.5—0.7
Industrial
Light
0.5—0.8
Heavy
0.6—0.9



Runoff Coefficient Adjustment Factor
Return Period
Cf 
1, 2, 5, 10
1.0
25
1.1
50
1.2
100
1.25



Universal Design Elements